With biological incubators the temperature validation is similar to above whereas the number of relative humidity measuring points is dependent on the chamber design (the ability to circulate air typically performed by a fan). For example, the acceptance criteria for a standard incubator with a set point of +37☌, is that all measurements throughout the chamber do not individually differ by more than 2☌ and all measurements maintain temperature around 32☌ to 37☌. Even most standard incubators provide access port(s) the cable feed through could disturb the integrity of the chamber atmosphere. For larger chambers it is recommended to place 5 measuring points on a minimum of 3 layers or on each layer with sample readings every 1- 5 minutes for 24, 48 or 72 hours.Įllab’s wireless loggers are ideal for such qualifications. During OQ these are fixed directly on the shelves in an empty chamber and during PQ they are placed into loaded samples. The typical number of measuring points is 5 (4 corners + center) on the lower and top shelf. The OQ also contains information about the calibration of measuring equipment and defines the location of the thermocouples and /or data loggers in the incubator. The OQ consists of temperature mapping of the empty chamber and is performed to confirm that the empty chamber works within the specified limits throughout the chamber. In the OQ, the performance of the incubator and its operational procedure is verified.

bod incubator temperature

The IQ is conducted to demonstrate that the incubator is inspected and contains all the required parts to ensure functionality. Validation of an incubator consists of various steps regarding Installation Qualification (IQ), Operational Qualifications (OQ) and Performance Qualifications (PQ). The standard applies for cabinets and incubators with a working temperature range from -10☌ to 300☌ and includes shaking incubators. Furthermore, DIN 12880-2 specifies performance requirements and tests for heating cabinets and incubators in laboratories. Subpart D describes handling of equipment (that it shall be routinely calibrated, inspected or checked according to a written program designed to assure proper performance). Climate Incubator (BJPX-AII) Constant Temperature Incubator (BJPX-HIV) CO2 Incubator BJPX-C160D. Low Temperature CO2 Incubator BJPX-C160III. Biochemistry Incubator (BJPX-I) Touch Screen Constant-Temperature Incubator.

bod incubator temperature

It also has a digital indicator accurate to + / -0.2C. Constant Temperature and Humidity Incubator (BJPX-HTBII) Platelet Incubator. The Bod Incubator has a temperature controller system, called a PID microprocessor. Great internal use in relation to the occupied area inside the laboratory. The Current Good Manufacturing Practice for manufacturing, processing, packing or holding of drugs and Current Good Manufacturing Practice for finished pharmaceuticals is described in 21 CFR Parts 210 and 211. The Bod Incubator is widely used in food industries, water and sewage companies, microbiology laboratories, genetics and elsewhere.















Bod incubator temperature